HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

5-3-14 HP_Location
HP_Location is used to model fan locations on ProLiant servers. The Windows® implementation class
is HP_WinFanLocation.
Table 5-15 Class: HP_Location
Property name Property implementation
CIM_ManagedElement
Caption Fan n, where n represents the fan position printed on
the system labeling.
Description The location of the fan n. Refer to fan position n printed
on the system.
ElementName Fan n, where n represents the fan position printed on
the system labeling.
CIM_Location
Name Unique identifier for this fan location instance
PhysicalPosition n, where n represents the fan position printed on the
system.
HP_Location
ElementLocationTag Fan n, where n represents the fan position printed on
the system.
ElementLocationTagDesc 0 (HoodTag)
5-3-15 HP_ElementLocation
HP_ElementLocation is used to represent an association between CIM_Location and
CIM_ManagedElement. The Windows® implementation class is HP_WinFanElementLocation.
Table 5-16 Class: HP_ElementLocation
Property name Property implementation
Element References CIM_ManagedElement
PhysicalLocation References CIM_Location
5-3-16 CIM_ConfigurationCapacity
CIM_ConfigurationCapacity is used to model fan configuration capacity on ProLiant Servers. The
Windows® implementation class is HP_WinFanConfigurationCapacity. There is one instance of this
class on systems modeling fan configuration capacity.
Table 5-17 Class: CIM_ConfigurationCapacity
Property name Property implementation