HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 5-11 Class: HP_FanSlot
Property name Property implementation
Number The physical fan slot number
SupportsHotPlug
True—If slot supports hot plug operations
False—If slot does not support hot plug operations
VendorCompatibilityStrings “HPQ:Fan”
HP_FanSlot
5-3-11 HP_FanInSlot
HP_FanInSlot is used to represent an association between HP_FanModule and HP_FanSlot that
contains this fan.
Table 5-12 Class: HP_FanInSlot
Property name Property implementation
Antecedent References HP_FanSlot
Dependent References HP_FanModule
5-3-12 HP_RealizesFan
HP_RealizesFan is used to represent an association between HP_Fan and HP_FanModule that realizes
this fan.
Table 5-13 Class: HP_RealizesFan
Property name Property implementation
Antecedent References HP_FanModule
Dependent References HP_Fan
5-3-13 HP_SystemPhysicalFan
HP_SystemPhysicalFan is used to represent an association between HP_FanModule and the computer
system that contains this fan.
Table 5-14 Class: HP_SystemPhysicalFan
Property name Property implementation
GroupComponent References HP_ComputerSystemChassis
PartComponent References HP_FanModule