HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 5-10 Class: HP_FanModule
Property name Property implementation
CIM_PhysicalPackage
PackageType 7 (Fan)
RemovalConditions 3 (Removable when off)
4 (Removable when on or off)
HP_Fan
5-3-10 HP_FanSlot
HP_FanSlot represents fan slot on ProLiant Servers. There is an instance of this class for each fan slot
in the system, whether or not the slot is occupied.
Table 5-11 Class: HP_FanSlot
Property name Property implementation
CIM_ManagedElement
Caption Fan n, where n represents the physical lot number
CIM_Managed SystemElement
HealthState
5 (OK)—If fan is operating properly
20 (Major Failure)—If fan has failed
Name Fan n, where n represents the physical lot number
OperationalStatus[0]
2 (OK)—If fan is operating properly
6 (Error)—If fan has failed
StatusDescriptions[0]
“Fan is operating properly”—If
OperationalStatus[0] is 2 (OK)
“Fan has failed”—If OperationalStatus is 6 (Error)
“Fan slot is empty” – if OperationalStatus[0] is
2(OK)
CIM_PhysicalElement
CreationClassName “HP_FanSlot”
Tag Fan n, where n represents the physical lot number
Description Fan n, where n represents the physical lot number
ElementName Fan n, where n represents the physical lot number
CIM_PhysicalConnector
ConnectorLayout 7 (Slot)
ConnectorPinout “Custom Fan Slot”
ConnectorType 76 (Proprietary)—Custom Fan slot
CIM_Slot