HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

5-3-8 HP_SystemFan
HP_SystemFan is used to represent an association between HP_Fan and the computer system that
contains this fan. The Windows® implementation class is HP_WinSystemFan.
Table 5-9 Class: HP_SystemFan
Property name Property implementation
GroupComponent References HP_ComputerSystem
PartComponent References HP_Fan
5-3-9 HP_FanModule
HP_FanModule is used to model the physical fans on ProLiant Servers. The Windows®-specific
implementation class is HP_FanModule.
NOTE: Fan numbers for existing instances do not change when other fans are added and removed.
Table 5-10 Class: HP_FanModule
Property name Property implementation
CIM_ManagedElement
Caption Fan n, where n represents the number of the fan
instance
Description Fan n provides cooling for FanType. StatusDescription
where n represents the number of the fan instance,
FanType represents the corresponding string value of
the FanType enumeration and StatusDescription
represents the value of StatusDescriptions[0]
ElementName Fan n, where n represents the number of the fan
instance
CIM_Managed SystemElement
OperationalStatus[0]
2 (OK)—If fan is operating properly
6 (Error)—If fan has failed
StatusDescriptions[0]
“Fan is operating properly”—If
OperationalStatus[0] is 2 (OK)
“Fan has failed”—If OperationalStatus is 6 (Error)
HealthState
5 (OK)—If fan is operating properly;
20 (Major Failure)—If fan has failed
Name Fan n, where n represents the number of the fan
instance
CIM_PhysicalElement
CreationClassName “HP_FanModule”
Tag Unique identifier for this fan module instance