HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet
HP Confidential
Table 4-30 HP_SensorHardwareIndication: Power Supply Redundancy Gained
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A fault tolerant power supply has been added to a
power redundancy set. (RedundancySetCaption), where
RedundancySetCaption is HP_WinPowerRedundancySet.
Caption of the redundancy set with an added power
supply
AlertingManagedElement WBEM path of the HP_WinPowerRedundancySet
instance representing the redundancy set with an
added power supply
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 7
ProviderName HP Power
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Power redundancy gained
EventCategory 16 (System Power)
ProbableCause 1 (Other)
ProbableCauseDescription Power Redundancy has been Gained
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>