HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management WBEM CPU Provider Overview 68
The following table lists the properties implemented. Any combination of the following applicable
descriptors could be used to better define the device location.
All Systems HP Integrity Cellular Servers
HP Blade Servers in
C3000/C7000 Enclosures
CPUSocket=<socket_num> on
System Mainboard
Cabinet=<cell_or_blade_cabi
net_num
>
_
ProcessorBoard=<
board_num>
Cell=<
cell_num
>
Blade=<
blade_num>
System Mainboard(referring
to motherboard)
_ _
CPUSocket=<socket_num> on
ProcessorBoard=<board
_num
>
_ _
3-4 Provider Indications
Indications Generated by the
Provider
The SMX CPU Provider generates WBEM indications described in the
following sections.
3-4-1 Common Properties for Provider Indications
The following table describes the properties that are common to all of the SMX CPU Provider indications
that are implemented for HP server platforms where available:
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication.
IndicationTime
Time of indication.
CIM_AlertIndication
EventTime
Time of the event or time of the indication if event time unknown.
SystemName
SMX_ComputerSystem.Name
SystemCreationClassName
SMX_ComputerSystem.CreationClassName
HP_AlertIndication
ProviderVersion
Provider Version in the format VV.UU.FF.
For example:
01.05.00