HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management WBEM System Memory Provider 422
17-3-4 SMX_MemoryIndication: Memory Redundancy
Degraded
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
5
(Major)
CIM_AlertIndication
Description
The AMP system is operating with degraded redundancy.
The targeted configuration has degraded or is operating
with memory modules that have failed or predicted to
fail. (TargetConfiguration/CurrentConfiguration)
Where: TargetConfiguration is
SMX_MemoryRedundancySet.TargetConfiguration
.
AlertingManagedElement
WBEM Path of SMX_MemoryRedundancySet instance representing the
Memory Redundancy.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
3
ProviderName
HP Memory
RecommendedActions
Check the Advanced Memory Protection configuration and
replace the memory board and memory modules as
necessary.
HP_AlertIndication
Summary
Advanced Memory Protection degraded
EventCategory
3
(Memory)
ProbableCause
88
(Loss of Redundancy)
ProbableCauseDescription
Advanced Memory Protection Degraded
17-3-5 SMX_MemoryIndication: Memory Recovered from
Degraded Redundancy
Property Name
Property Implementation
CIM_Indication