HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management WBEM System Memory Provider 421
Property Name
Property Implementation
Summary
Memory module has failed or is predicted to fail
EventCategory
3
(Memory)
ProbableCause
1
(Other)
ProbableCauseDescription
Memory Module Failed or Predicted to Fail
17-3-3 SMX_MemoryIndication: Memory Board Error
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5
(Major)
CIM_AlertIndication
Description
A memory board has an error. (MemoryBoardCaption)
Where: MemoryBoardCaption is the SMX_MemoryBoard.Caption for
the failing memory board.
AlertingManagedElement
WBEM Path of
SMX_MemoryBoard
instance representing the memory board
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
2
ProviderName
HP Memory
RecommendedActions
Check the memory configuration and replace the memory
board and memory modules as necessary.
HP_AlertIndication
Summary
Memory board error
EventCategory
3
(Memory)
ProbableCause
1
(Other)
ProbableCauseDescription
Memory Board Error