HP Insight Management WBEM System Memory Provider 420
Property Name
Property Implementation
SystemModel
Model name of the computer system generating the indication
SystemGUID
Platform GUID of the computer system generating the indication
SystemVirtualUUID[]
If Synergy is enabled, this will contain the logical UUID for the system.
SystemVirtualSerialNumber[]
If Synergy is enabled, this will contain the logical Serial Number for the
system.
EnclosureName
HP_BladeEnclosureCS.Name
RackName
Rack name, if one exists
RackUUID
Rack Unique Identifier, if one exists
BladeName
HP_ComputerSystem.Name
BladeBay
HP_BladeCSLocation.LocationInformation[0]
17-3-2 SMX_MemoryIndication: Memory Module Predictive
Failure
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
5
(Major)
CIM_AlertIndication
Description
A memory module has failed or is predicted to fail.
(MemoryModuleCaption) where MemoryModuleCaption is the
SMX_MemoryModule.Caption
for the failing memory module
AlertingManagedElement
WBEM Path of SMX_MemoryModule instance representing the memory
module
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
1
ProviderName
HPMemory
RecommendedActions
Check the memory configuration and replace memory as
necessary.
HP_AlertIndication