HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management WBEM System Memory Provider 415
Property Name
Property Implementation
GroupOperationalStatus
Enumerator indicating the group operational status of the memory collection.
The status is determined as follows:
• If an instance of SMX_MemoryRedundancySet exists,
GroupOperationalStatus[0] is determined from the property
SMX_MemoryRedundancySet.RedundancyStatus
.
• If no instance of SMX_MemoryRedundancySet exists,
GroupOperationalStatus[0] is determined by the ‘worst-of’
algorithm for physical memory boards and memory modules
.
For details, see “Properties for Memory Collection Status”.
GroupStatusDescriptions
GroupStatusDescriptions[0] contains descriptive text per
GroupOperationalStatus[0]:
Memory collection status: OK
Memory collection status: Degraded
Memory collection status: Unknown
HP_MemoryCollection
17-2-18-1 Properties for Memory Collection Status
RedundancyStatus
‘worst’ ‘worst’
GroupOperational
Status[0]
from
OperationalStatu
s[0]
,
OperationalStatus[0],
SMX_MemoryRedundancySet
SMX_MemoryBoard
SMX_MemoryModule
2
(Fully Redundant)
- -
2
(OK)
3
(Degraded Redundancy) - -
3
(Degraded)
-
2
(OK)
2
(OK)
2
(OK)
-
2
(OK)
3
(Degraded)
3
(Degraded)
-
2
(OK)
0
(Unknown)
0
(Unknown)
-
3
(Degraded)
2
(OK)
3
(Degraded)
-
3
(Degraded)
3
(Degraded)
3
(Degraded)
-
3
(Degraded)
0
(Unknown)
3
(Degraded)