HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
Property Name
Property Implementation
redundancy set with reduced redundancy.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
5
ProviderName
HP Cooling
RecommendedActions
No action is recommended.
HP_AlertIndication
Summary
Cooling redundancy reduced
EventCategory
23
(System Cooling)
ProbableCause
88
(Loss of Redundancy)
ProbableCauseDescription
Cooling Redundancy has been Reduced
16-3-8 DeviceIndication: Fan Redundancy Lost
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
4
(Minor)
CIM_AlertIndication
Description
Cooling redundancy has been lost. <RedundancySetCaptio>)
Where: <RedundancySetCaption> represents the
SMX_FanRedundancySet.Caption for the redundancy set that lost
redundancy.
AlertingManagedElement
WBEM Path of SMX_FanRedundancySet instance representing the
redundancy set where redundancy was lost.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
6
ProviderName
HP Cooling
RecommendedActions
Check the fan configuration and check the status of the
cooling redundancy. Ensure the system is being cooled
adequately. Add or replace fans if necessary.