HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
4
(Minor)
CIM_AlertIndication
Description
A fan has degraded. <FanCaption>
Where: <FanCaption> is the SMX_Fan.Caption for the fan that has
degraded.
AlertingManagedElement
WBEM Path of
SMX_Fan
instance representing the degraded fan.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
9
ProviderName
HP Cooling
RecommendedActions
Check the degraded fan and replace if necessary.
HP_AlertIndication
Summary
Fan degraded
EventCategory
23
(System Cooling)
ProbableCause
1
(Other)
ProbableCauseDescription
Fan Degraded
16-3-7 HP_DeviceIndication: Fan Redundancy Reduce
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description
A fault tolerant fan is no longer providing cooling for a cooling redundancy
set. <RedundancySetCaptio>)
Where: <RedundancySetCaption> represents the
SMX_FanRedundancySet.Caption for the redundancy set with reduced
redundancy.
AlertingManagedElement
WBEM Path of
SMX_FanRedundancySet
instance representing the