HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
Property Name
Property Implementation
ProbableCause
94
(Fan Failure)
ProbableCauseDescription
Fan Failed
16-3-5 HP_DeviceIndication: Fan Repaired
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
2
(Information)
CIM_AlertIndication
Description
A fan has been repaired. The fan is now operating properly.
<FanCaption>
Where: <FanCaption> is the SMX_Fan.Caption for the fan that has
been repaired.
AlertingManagedElement
WBEM Path of
SMX_Fan
instance representing the failed fan.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
4
ProviderName
HP Cooling
RecommendedActions
No action is recommended.
HP_AlertIndication
Summary
Fan repaired
EventCategory
23
(System Cooling)
ProbableCause
1
(Other)
ProbableCauseDescription
Fan Repaired
16-3-6 HP_DeviceIndication: Fan Degraded
Important: This indication is not supported on HP ProLiant systems because the fans do not report a
degraded status.
Property Name Property Implementation