HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

Property Name
Property Implementation
GroupComponent
References
HP_ComputerSystemChassis
PartComponent
References
HP_FanSlot
16-2-16 SMX_FanInSlot Class
The SMX_FanInSlot class implements the HP_FanInSlot class and associates the HP_FanSlot instance
with
HP_FanModule instances.
The following table lists the properties implemented.
Property Name
Property Implementation
Antecedent
References
HP_FanSlot
Dependent
References
HP_FanModule
16-2-17 SMX_FanSpeedSensor
SMX_FanSpeedSensor implements CIM_NumericSensor and is used to model fan tachometer sensors
on Servers.
Property Name
Property Implementation
CIM_ManagedElement
Caption
Short description of the fan speed sensor from the name displayed by the MP
or iLO and the location.
For example:
Fan speed sensor for Fan 1 at CabinetFan=01
Description
Description of the fan speed sensor including name displayed by the MP or
iLO, the location, and status.
For example:
Fan 1 detects fan speed. Located at CabinetFan=01.
Fan speed sensor is operating properly.
ElementName
Short description of the fan speed sensor from the name displayed by the MP
or iLO and the location.
For example:
Fan speed sensor for Fan 1 at CabinetFan=01
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) if fan sensor is operating properly