HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_ManagedElement
Caption
Short description of this fan from the name displayed by the MP or iLO and
location.
For example:
Fan 1 at CabinetFan=01
Description
Description of this fan module, including ElementName, type and status.
For example:
<ElementName> provides cooling for FanType. <StatusDescription>
Where: <ElementName> represents the value of ElementName, FanType
represents the corresponding string value of the FanType enumeration and
<StatusDescription> represents the value of
StatusDescriptions[0]
.
ElementName
Name of this fan from the name displayed by the MP or iLO and location.
For example:
Fan 1 at CabinetFan=01
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) – if fan is operating properly;
3 (Degraded) – if fan is degraded;
6
(Error) – if fan has failed
StatusDescriptions[0]
Description of the status of the fan corresponding to the
OperationalStatus.
For example:
Fan is operating properly – if OperationalStatus[0] is 2 (OK);
Fan is degraded – if OperationalStatus[0] is 3 (Degraded)
Fan has failed
– if
OperationalStatus
is
6
(Error)
HealthState
5 (OK) – if fan is operating properly;
10 (Degraded) if fan is degraded
20
(Major Failure) – if fan has failed
Name
Name of this fan module.
For example:
Fan 1 at CabinetFan=01
CIM_PhysicalElement
CreationClassName