HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
16-2-3 SMX_FanRedundancySet Class
The SMX_FanRedundancySet class is used to model fan redundancy sets on servers.
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_ManagedElement
Caption
Short description of this redundancy set, for example: Cooling
Redundancy Set <n>
Where:
<
n> represents the number of the redundancy set instance.
Description
Description of this redundancy set
For example:
Cooling Redundancy Set <n> is collection of fault tolerant fans that
provide redundant cooling
Where:
<
n> represents the number of the redundancy set instance.
ElementName
User printable name for this cooling redundancy set.
For example:
Cooling Redundancy Set <n>
Where:
<
n> represents the number of the redundancy set instance.
CIM_SystemSpecificCollection
InstanceID
Unique identifier for this cooling redundancy instance.
CIM_RedundancySet
MaxNumberSupported
Represents the maximum number of fans supported for this redundancy set.
MinNumberNeeded
Represents the minimum number of fans needed to function.
TypeOfSet
3
(Load Balanced)
LoadBalanceAlgorithm
0
(Unknown)
RedundancyStatus
0 (Unknown) – if the redundancy status is unknown;
2 (Fully Redundant) – if all fans in the set are operating properly and enough
to achieve redundancy;
3 (Degraded Redundancy) – if there are at least enough fans for the
redundancy set to provide cooling, but fans have failed;
4 (Redundancy Lost) – if there are not enough fans required to achieve
redundancy, but enough for the redundancy set to provide cooling;
5
(Overall Failure) – if there are not enough fans operating properly for the