HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

The following table lists the properties implemented.
Property Name
Property Implementation
CIM_ManagedElement
Caption
Cooling Collection
Description
This is a collection of all devices including fans that provide cooling.
GroupStatusDescription
Where: GroupStatusDescription represents the value of the
GroupStatusDescriptions[0]
property.
ElementName
Cooling Collection
CIM_SystemSpecificCollection
InstanceID
Unique identifier for this cooling collection instance.
HP_GroupSystemSpecificCollection
GroupOperationalStatus[
0]
Represents the most severe cooling redundancy status and non-fault tolerant
fan operational status:
0 (Unknown) if fan collection status is unknown;
2 (OK) if fans are operating properly;
3 (Degraded) if no SMX_Fan.OperationalStatus[0] for all non-fault
tolerant fans report 6 (Error) and
SMX_FanRedundancySet.RedundancyStatus for any cooling
redundancy sets report 3 (Degraded Redundancy) or 4
(Redundancy Lost) and
no cooling redundancy sets report 5 (Overall Failure).
6 (Error) if SMX_Fan.OperationalStatus[0] for any non-fault tolerant
fans report 6 (Error) or SMX_FanRedundancySet.RedundancyStatus for
any cooling redundancy sets report 5 (Overall Failure).
Note: If the system starts up with a redundancy status set to 4 (Redundancy
Lost) and no fans have been removed or failed, the
GroupOperationalStatus will be set to 2 (OK) because this is a valid
configuration.
GroupStatusDescriptions
[0]
Unknown status for fans if GroupOperationalStatus[0] is 0
(Unknown);
Fans are operating properly if GroupOperationalStatus[0] is
2 (OK);
Fault tolerant fans are degraded if
GroupOperationalStatus[0] is 3 (Degraded);
Fans have failed
if
GroupOperationalStatus[0]
is
6
(Error)