HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management WBEM Smart Array Provider 360
Property Name Property Implementation
HWLogicalLocation
Enclosure Location string
For example:
Port 1I Box 1
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
15-3-24 HP_DeviceIndication: Enclosure Temperature sensor
Status Changed to Critical
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5
(major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Temperature sensor status has
changed to Critical. An enclosure temperature is
reaching the maximum allowed temperature for normal
operation. A shutdown is imminent. Action is required
before loss of data occurs.
AlertingManagedElement
WBEM Path of
SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
309
EventTime
Time of the event or time of the indication if event time unknown
Provider
Name
HP Smart Array
RecommendedActions
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication