HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management WBEM Smart Array Provider 354
Property Name Property Implementation
PerceivedSeverity
3
(Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Power Subsystem status has changed
to Degraded Redundancy.
AlertingManagedElement
WBEM Path of
SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
303
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
RecommendedActions
Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName
of the computer system generating the indication
HP_AlertIndication
Summary
Power supply status Redundant Degraded
EventCategory
17
(Primary Storage Power)
ProbableCause
89
(Power supply failure)
ProbableCauseDescription
Redundant Power Supply Degraded
NetworkAddresses
Contains a list of all the IP addresses of the computer system generating the
indication
OSType
SMX_OperatingSystem.OSType
OSVersion
The operating system version of the computer system generating the
indication in the following format:
<
major
>.<
minor
>.<
build
>
ProviderVersion
For example:
2.2.0.0