HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management WBEM Smart Array Provider 344
Property Name Property Implementation
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber
Conditional property containing the virtual system serial number string
when running in a Virtual Connect environment
SystemGUID
Platform GUID of the computer system generating the indication
VariableNames[]
FailureDescription
CacheSizeTotal
CacheSerialNumber
VariableTypes[]
String (1)
uint32 (5)
VariableValues[]
FailureDescriptionshort description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel
Array Controller Model string
15-3-17 HP_DeviceIndication: Controller Cache Status -
Temporarily Disabled
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2
(Info)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Smart Array controller Cache status has changed to
Temporarily Disabled. This may be caused by a rebuild
or configuration change. Normal operation will return
after background operations have completed.
AlertingManagedElement
WBEM Path to
SMX_SAArrayController
class.
AlertingElementFormat
2
(CIMObjectPath)