HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management WBEM Smart Array Provider 337
Property Name Property Implementation
HP_DeviceIndication
DeviceModel
Array Controller Model string
15-3-14 HP_DeviceIndication: Controller Battery Status Changed
to not fully charged
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3
(Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Smart Array controller Battery status has changed to
Not Fully Charged.
AlertingManagedElement
WBEM Path to
SMX_SAArrayController
class.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
7
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
RecommendedActions
Check battery operation, allow time to the battery to
be fully charged.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName
of the computer system generating the indication
HP_AlertIndication
Summary
Controller Battery Status set to Not fully Charged.
EventCategory
6
(Primary Storage)
ProbableCause
99
(low battery)