HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management WBEM Smart Array Provider 332
Property Name Property Implementation
HP_DeviceIndication
DeviceModel
Array Controller Model string
15-3-12 HP_DeviceIndication: Controller Redundancy has been
restored
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2
(Info)
IndicationTime
Time of indication
CIM_AlertIndication
Description
Controller has detected that Redundancy has been
restored and can communicate with partner controller.
AlertingManagedElement
WBEM Path to
SMX_SAArrayController
class.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
5
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
RecommendedActions
No action is recommended.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName
of the computer system generating the indication
HP_AlertIndication
Summary
Controller redundancy restored
EventCategory
6
(Primary Storage)
ProbableCause
1
(Other)