HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management WBEM Smart Array Provider 327
Property Name Property Implementation
HP_DeviceIndication
DeviceModel
Array Controller Model string
15-3-10 HP_DeviceIndication: Controller Redundancy state has
been set to Active
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3
(Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Smart Array controller redundancy state has changed
from Standby to Active.
AlertingManagedElement
WBEM Path to
SMX_SAArrayController
class.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
3
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
RecommendedActions
Check status of all controllers. An array controller
may have failed causing this controller to become
active.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName
of the computer system generating the indication
HP_AlertIndication
Summary
Controller redundancy state set to Active
EventCategory
6
(Primary Storage)
ProbableCause
1
(Other)