HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management WBEM Smart Array Provider 321
Property Name Property Implementation
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
Note:
When ImpactedDomain is 3 (Enclosure) the properties that follow
and are indicated with an asterisk (*) below will be populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name, if one exists
RackUID *
Rack Unique Identifier, if one exists
SystemVirtualSerialNumber
Conditional property containing the virtual system serial number
string when running in a Virtual Connect environment
SystemVirtualUUID
Conditional property containing the virtual system UUID when
running in a Virtual Connect environment
HP_HardwareIndication
HWLogicalLocation
Logical drive number & RAID Level.
For example:
LogicalDrive 1
(RAID 1+0).
VariableNames[]
FailureDescription
VariableTypes[]
String (1)
VariableValues[]
FailureDescription
short description of the failure
HP_DeviceIndication
SMX_SAStorageVolumeIndication
DeviceOperationalStatus
Current OperationStatus values for Storage Volume
DeviceOperationalStatus[0]:
SMX_SAStorageVolume.OperationalStatus[0]
DeviceOperationalStatus[1]:
SMX_SAStorageVolume.OperationalStatus[1]
(This index is only populated if there is additional Vendor unique
status available)