HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management WBEM Smart Array Provider 319
Property Name Property Implementation
VariableValues[]
FailureDescription
short description of the failure
HP_DeviceIndication
SMX_SAStorageVolumeIndication
DeviceOperationalStatus
Current OperationStatus values for Storage Volume
DeviceOperationalStatus[0]:
SMX_SAStorageVolume.OperationalStatus[0]
DeviceOperationalStatus[1]:
SMX_SAStorageVolume.OperationalStatus[1]
(This index is only populated if there is additional Vendor unique
status available)
DeviceOperationalStatusPrevious
Previous OperationStatus values for Storage Volume
DeviceOperationalStatusPrevious[0]:
SMX_SAStorageVolume.OperationalStatus[0]
DeviceOperationalStatusPrevious[1]:
SMX_SAStorageVolume.OperationalStatus[1]
(This index is only populated if there is additional Vendor unique
status available)
15-3-7 SMX_SAStorageVolumeIndication: Logical Drive Status
Changed to Degraded
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2
(Info)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A logical drive is in a degraded state. Device
is still servicing I/O but redundancy may be
degraded or lost.
AlertingManagedElement
WBEM Path of
SMX_SAStorageVolume
class
AlertingElementFormat
2
(CIMObjectPath)