HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management WBEM Smart Array Provider 317
15-3-6 SMX_SAStorageVolumeIndication: Logical Drive Status
Changed to ERROR
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5
(Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A logical drive status has changed to Error.
AlertingManagedElement
WBEM Path of
SMX_SAStorageVolume
class
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
102
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
RecommendedActions
Check for failed or removed physical drives.
SystemName
Name
of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary
Logical drive status error
EventCategory
6
(Primary Storage)
ProbableCause
86
(Disk Failure)
ProbableCauseDescription
Logical Drive Status Changed to Error
NetworkAddresses
Contains a list of all the IP addresses of the computer system
generating the indication
OSType
SMX_OperatingSystem.OSType