HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management WBEM Smart Array Provider 314
Property Name Property Implementation
VariableTypes[]
String (1)
uint16 (4)
VariableValues[]
FailureDescription – short description of the failure
Drive interface HPSA_DiskDrive.DriveInterface
LastFailureDescription – last failure reason string from the
drive. HPSA_DiskDrive.OperationalStatus[1]
HP_DeviceIndication
DeviceModel
Physical Disk Model string
DeviceControllerLogicalLocation
Controller Location
For example:
SmartArray 642 in Slot 2
15-3-5 HPSA_StorageVolumeIndication: Logical Drive Status
Changed to OK
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2
(Informational)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A logical drive status has changed from a non-OK
state to OK.
AlertingManagedElement
WBEM Path of
SMX_SAStorageVolume
Class
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
101
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array