HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management WBEM Smart Array Provider 312
Property Name Property Implementation
PerceivedSeverity
5
(Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A physical drive status has changed to
Predictive Failure.
AlertingManagedElement
WBEM Path of
SMX_SADiskDrive
class
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
204
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
(
RecommendedActions
Replace drive immediately to avoid loss of data.
SystemName
Name
of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary
Physical drive status Predictive Failure.
EventCategory
6
(Primary Storage)
ProbableCause
86
(Disk Failure)
ProbableCauseDescription
Physical Drive Status Changed to Predictive
Failure.
NetworkAddresses
Contains a list of all the IP addresses of the computer system
generating the indication
OSType
SMX_OperatingSystem.OSType
OSVersion
The operating system version of the computer system generating the
indication in the following format:
<
major
>.<
minor
>.<
build
>
ProviderVersion
For example:
2.2.0.0