HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Manager WBEM Base Server Provider Overview 31
Property Name
Property Implementation
ProbableCause
15
(Temperature Unacceptable)
ProbableCauseDescription
Thermal reboot occurred
1-3-7 HP_DeviceIndication: POST Occurred
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5
(Warning)
CIM_AlertIndication
Description Power-On Self-Test errors occurred during the last
system startup.
AlertType
5
(Device Alert)
EventID
3
ProviderName
HP Recovery
RecommendedActions Determine the nature of the POST error and take
corrective action.
HP_AlertIndication
Summary
POST errors occurred
EventCategory
4
(System Harware)
ProbableCause
8
(Configuration/Customization Error)
ProbableCauseDescription
POST Errors occurred
VariableName VariableNames[0]: POST Error Code
VariableNames[1]: POST Error String
VariableType VariableTypes[0]: 3 (uint8)
VariableTypes[1]: 1 (string)
VariableValue VariableValues[0]: The POST error code as specified
by the System ROM
VariableValues[1]: The POST error string as specified
by the System ROM