HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management WBEM Smart Array Provider 267
Property Name Property Implementation
IdentityInfoType
[0]CIM:SoftwareFamily
[1]HPQ:SoftwareCategory
IdentityInfoValue
[0]HPQ:<TargetType value>
[1]StorageDevice
VersionString
Enclosure firmware string
HPSA_EnclosureFirmware
15-2-16 SMX_SAPrimordialPool Class
The SMX_SAPrimordialPool class implements the HPSA_PrimordialPool class and represents the
total raw storage managed by the array controller. There is one instance per array system.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
ElementName
Controller name and <physical location>.
Refer to
“Physical Location” for more information.
For example:
“Smart Array in Slot=3” for internal
For example:
“Smart Array Embedded Controller=7” for embedded controller where
7 is the internal identifier for the embedded controller.
CIM_ManagedSystemElement
CIM_LogicalElement
CIM_StoragePool
InstanceID
Opaque key
PoolID
Controller serial number
Primordial
Always set to
TRUE
RemainingManagedSpace
Remaining raw space on controller. This is calculated by summing the
remaining space on all drives attached to the controller.
TotalManagedSpace
Total raw space available to controller. This is calculated by summing