HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management WBEM Smart Array Provider 257
Property Name Property Implementation
CIM_SoftwareIdentity
ClassificationDescriptions[0]
Disk Drive Firmware
Classifications[0]
10
(Firmware)
InstanceID
Opaque key
Manufacturer
Disk drive vendor string
IdentityInfoType
[0]CIM:SoftwareFamily
[1]HPQ:SoftwareCategory
IdentityInfoValue
[0]HPQ:<TargetType value>
[1]Storage Device
VersionString
Drive firmware as reported from SCSI identify command
HPSA_DiskDriveFirmware
15-2-7 SMX_SAPhysicalPackage Class
The SMX_SAPhysicalPackage class implements the HPSA_PhysicalPackage class and represents the
overall physical package for the array system as a whole. There is one instance per HBA or Storage
Subsystem.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
ElementName
Controller/Storage System name and <physical location>.
Refer to
“Physical Location” for more information.
Description
Host Based RAID Controller
( For Internal Controller)
CIM_ManagedSystemElement
Name
See Serial number implementation
CIM_PhysicalElement
CreationClassName
SMX_SAPhysicalPackage
Manufacturer