HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management WBEM Smart Array Provider 252
Property Name Property Implementation
CIM_ManagedElement
ElementName
Logical drive number with raid Description
For example:
Logical Volume 1
(RAID 1+0)
CIM_ManagedSystemElement
Name
VPD Pg83 identifier for the volume.
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault
2
(Enabled)
EnabledState
5
(Not Applicable)
RequestedState
12
(Not Applicable)
CIM_LogicalDevice
CreationClassName
SMX_SAStorageVolume
DeviceID
Opaque Key
SystemCreationClassName
SMX_SAArraySystem
SystemName
SMX_SAArraySystem.Name
CIM_StorageExtent
ConsumableBlocks
0
BlockSize
Block Size in bytes
DataRedundancy
1 (RAID 0, RAID 5, RAID 6), RAID 50, RAID 60
2 (RAID 1+0)
DeltaReservation
0
ExtentStatus[0]
This will indicate extended status for the volume.
2 (None)
11
(Rebuild Volume is currently rebuilding data)
IsBasedOnUnderlyingRedundancy
False