HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management WBEM Smart Array Provider 250
Property Name Property Implementation
ElementName
Controller name and <physical location>.
Refer to
“Physical Location” for more information.
For example:
“Smart Array in Slot=3” for internal
For example:
“Smart Array Embedded Controller=7” for embedded controller where 7
is the internal identifier for the embedded controller.
CIM_ManagedSystemElement
OperationalStatus[0]
Status for Array Controller.
0 (Unknown)
2 (OK)
6
(Error)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault
2
(Enabled)
EnabledState
5
(Not Applicable)
RequestedState
12
(Not Applicable)
CIM_System
CreationClassName
SMX_SAArrayController
Name
Controller Serial Number.
EMBEDDED-<id> will be reported if there is no Serial Number.
For example: embedded on motherboard.
PCISLOT-<Slot number> will be reported if there is no Serial Number
and the controller is in a PCI slot
Where: <Slot number> is the number of PCI slot.
NameFormat
Other
CIM_ComputerSystem
Dedicated
Dedicated[0]
0
(Not Dedicated)
HPSA_Arraycontroller