HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management WBEM System Temperature Sensor Provider 242
Property Name
Property Implementation
SystemFirmwareVersion
Firmware version of the computer system generating the indication.
SystemSerialNumber
Serial number of the computer system generating the indication.
SystemProductID
Product ID of the computer system generating the indication.
SystemModel
Model name of the computer system generating the indication.
SystemGUID
Platform GUID of the computer system generating the indication.
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
Note:
When ImpactedDomain is 3 (Enclosure) the properties indicated with (*)
below will be populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name, if one exists.
RackUID *
Rack Unique Identifier, if one exists.
SystemVirtualSerialNumber
Conditional property containing the virtual system serial number string
when running in a Virtual Connect environment.
SystemVirtualUUID
Conditional property containing the virtual system UUID when running in a
Virtual Connect environment.