HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management WBEM System Temperature Sensor Provider 241
Property Name
Property Implementation
IndicationTime
Time of indication.
CIM_AlertIndication
Description
A temperature sensor has detected that the temperature
has returned to a normal operating range.
<SensorCaption>
Where: <SensorCaption> is the SMX_NumericSensor.Caption for
the temperature sensor detecting a recovered exceeded threshold.
AlertingManagedElement
WBEM Path of SMX__NumericSensor instance representing the
temperature sensor detecting a recovered exceeded threshold.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
2
EventTime
Time of the event or time of the indication if event time unknown.
ProviderName
HP Temperature
RecommendedActions
No action is recommended.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Threshold exceeded condition recovery
EventCategory
23
(System Cooling)
ProbableCause
52
(Threshold Crossed)
ProbableCauseDescription
Threshold Exceeded Condition has Recovered
ProviderVersion
For example: 2.2.0.0
NetworkAddresses
Contains a list of all the IP addresses of the computer system generating the
indication.
OSType
SMX_OperatingSystem.OSType
OSVersion
The operating system version of the computer system generating the
indication in the following format:
major
.
minor
.
build