HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management WBEM System Temperature Sensor Provider 234
Property Name
Property Implementation
the number of the temperature sensor instance, NumericSensorType
represents the value of NumericSensorTypeand StatusDescription
represents the value of
StatusDescriptions[0]
.
ElementName
“Temperature Sensor <sensorID>”
Where: <sensorID> is the name displayed by the MP or iLO.
For example:
Temperature Sensor Temp 1
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) if temperature reported by the sensor is within normal operating
range;
2 (OK) if temperature reported by the sensor has exceeded its non-critical
threshold and has set fans to full speed;
6 (Error) if temperature reported by the sensor has exceeded its threshold
and the system is gracefully shutting down.
StatusDescriptions[0]
Temperature reported by the sensor is within normal
operating range – if temperature reported by the sensor is within
normal operating range;
Temperature reported by the sensor has exceeded its
non-critical threshold and the fans have been set to
full speedif temperature reported by the sensor has exceeded its
threshold and has set fans to full speed;
Temperature reported by the sensor has exceeded its
threshold and the system is gracefully shutting down if
OperationalStatus is 6 (Error)
HealthState
5 (OK) if OperationalStatus[0] value is 2 (OK);
20
(Major Failure)if
OperationalStatus[0]
value is
6
(Error)
Name
Temperature Sensor n where n represents the number of the
temperature sensor instance(s).
CIM_LogicalDevice
CreationClassName
SMX_NumericSensor
DeviceID
Unique identifier for this temperature sensor instance.
SystemCreationClassName
HP_ComputerSystem.CreationClassName
SystemName
HP_ComputerSystem.Name
CIM_EnabledLogicalElement