HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management Power Supply Provider Overview 224
12-3-10 HP_DeviceIndication: Power Supply Redundancy Failed
Important: This indication is not supported on HP Proliant systems since redundancy set
failure, which is failure beyond redundancy lost, will cause system shutdown.
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5
(Major)
CIM_AlertIndication
Description
Power redundancy has been lost. RedundancySetCaption
Where: RedundancySetCaption represents the
SMX_PowerRedundancySet.Caption for the redundancy set that failed
redundancy.
AlertingManagedElement
WBEM Path of SMX_PowerRedundancySet instance representing the
redundancy set where redundancy failed.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
20
ProviderName
HP Power
RecommendedActions
Check the power supply configuration and check the
status of the power redundancy. Ensure the system is
being powered adequately. Add or replace power supplies
if necessary.
HP_AlertIndication
Summary
Power redundancy failed
EventCategory
16
(System Power)
ProbableCause
88
(Loss of Redundancy)
ProbableCauseDescription
Power Redundancy has Failed
12-3-11 HP_DeviceIndication: Power Supply Redundancy
Restored
Property Name Property Implementation