HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management Power Supply Provider Overview 223
Property Name
Property Implementation
ProbableCause
88
(Loss of Redundancy)
ProbableCauseDescription
Power Redundancy has been Reduced
12-3-9 HP_DeviceIndication: Power Supply Redundancy Lost
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
4
(Minor)
CIM_AlertIndication
Description
Power redundancy has been lost. RedundancySetCaption
Where: RedundancySetCaption represents the
SMX_PowerRedundancySet.Caption for the redundancy set that lost
redundancy.
AlertingManagedElement
WBEM Path of SMX_PowerRedundancySet.Caption instance
representing the redundancy set where redundancy was lost.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
6
ProviderName
HP Power
RecommendedActions
Check the power supply configuration and check the
status of the power redundancy. Ensure the system is
being powered adequately. Add or replace power supplies
if necessary.
HP_AlertIndication
Summary
Power redundancy lost
EventCategory
16
(System Power)
ProbableCause
88
(Loss of Redundancy)
ProbableCauseDescription
Power Redundancy has been Lost