HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management Power Supply Provider Overview 221
Property Name
Property Implementation
Where: PowerSupplyCaption is the SMX_PowerSupply.Caption for
the power supply that has degraded.
AlertingManagedElement
WBEM Path of SMX_PowerSupply instance representing the degraded
power supply.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
20
ProviderName
HP Power
RecommendedActions
Check the degraded power supply and replace if
necessary.
HP_AlertIndication
Summary
Power supply degraded
EventCategory
16
(System Power)
ProbableCause
1
(Other)
ProbableCauseDescription
Power supply degraded
12-3-7 HP_DeviceIndication: Power Supply Repaired
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
2
(Information)
CIM_AlertIndication
Description
A power supply has been repaired. PowerSupplyCaption
Where: PowerSupplyCaption is the SMX_PowerSupply.Caption for
the power supply that has been repaired.
AlertingManagedElement
WBEM Path of SMX_PowerSupply instance representing the repaired
power supply.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
4