HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management Power Supply Provider Overview 220
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5
(Major)
CIM_AlertIndication
Description
A power supply has failed. PowerSupplyCaption
Where: PowerSupplyCaption is the SMX_PowerSupply.Caption for
the power supply that has failed.
AlertingManagedElement
WBEM Path of SMX_PowerSupply instance representing the failed power
supply.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
3
ProviderName
HP Power
RecommendedActions
Check the failed power supply and replace if necessary
.
HP_AlertIndication
Summary
Power supply failed
EventCategory
16
(System Power)
ProbableCause
89
(Power Supply Failure)
ProbableCauseDescription
Power Supply Failed
12-3-6 HP_DeviceIndication: Power Supply Degraded
Important: This indication is not supported on HP Proliant systems as the power supplies
do not report a degraded status.
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
5
(Major)
CIM_AlertIndication
Description
A power supply has failed. PowerSupplyCaption