HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management Power Supply Provider Overview 217
Property Name
Property Implementation
OSVersion
The operating system version of the computer system generating the
indication in the following format:
major
.
minor
.
build
SystemFirmwareVersion
Array of firmware versions of the computer system generating the
indication.
SystemSerialNumber
Serial number of the computer system generating the indication.
SystemProductID
Product ID of the computer system generating the indication.
SystemModel
Model name of the computer system generating the indication.
SystemGUID
Platform GUID of the computer system generating the indication.
SystemVirtualUUID
[] If Synergy is enabled, this will contain the logical UUID for the system.
SystemVirtualSerialNumber[]
If Synergy is enabled, this will contain the logical Serial Number for the
system.
EnclosureName
HP_BladeEnclosureCS.Name
RackName
Rack name if one exists
RackUUID
Rack Unique Identifier if one exists
BladeName
HP_ComputerSystem.Name
BladeBay
HP_BladeCSLocation.LocationInformation[0]
12-3-2 HP_DeviceIndication: Power Supply AC Input Loss
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
5
(Major)
CIM_AlertIndication
Description
A power supply has failed input power lost. PowerSupplyCaption
Where: PowerSupplyCaption is the SMX_PowerSupply.Caption for
the power supply that has failed
AlertingManagedElement
WBEM Path of SMX_PowerSupply instance representing the failed power
supply
AlertingElementFormat
2
(CIMObjectPath)