HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management Power Supply Provider Overview 213
Property Name
Property Implementation
PowerSupplySlot=1.
CIM_LogicalDevice:
CreationClassName
SMX_PowerMeter
DeviceID
Unique identifier for this power utilizaton sensor.
SystemCreationClassName
SMX_ComputerSystem.CreationClassName
SystemName
SMX_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault
2
(Enabled)
EnabledState
5
(Not Applicable)
RequestedState
12
(Not Applicable)
CIM_Sensor
SensorType
13
(Power Consumption)
CurrentState
“Normal”
PossibleStates
Array may contain the following value:
PossibleStates[0] = “Normal”
CIM_NumericSensor
CurrentReading
Current reading of the power meter
BaseUnits
7
(Watts)
RateUnits
0
(None)
UnitModifier
0
12-2-18 SMX_SystemPowerMeter
SMX_SystemPowerMeter class and associates the HP_ComputerSystem instance with
HP_PowerMeter.