HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management Power Supply Provider Overview 211
Property Name
Property Implementation
StatusDescriptions[0]
Power supply slot is operating properly – if
OperationalStatus[0]
is
2
(OK)
HealthState
5
(OK) – if power supply is operating properly
Name
Name of the power supply slot.
For example:
PowerSupplySlot=2
CIM_PhysicalElement
CreationClassName
SMX_PowerSupplySlot
Tag
Unique identifier for this power supply slot.
CIM_PhysicalPackage
ConnectorLayout
6
(Slot)
Number
<n>
Where: <n> represents the number of the power supply slot.
12-2-15 SMX_SystemPowerSupplySlot Class
The SMX_SystemPowerSupplySlot class extends the CIM_Container class and association of
the HP_ComputerSystemChassis instance with HP_PowerSupplySlot.
The following table lists the properties implemented.
Property Name
Property Implementation
GroupComponent
References
HP_ComputerSystemChassis
PartComponent
References
HP_PowerSupplySlot
12-2-16 SMX_PowerSupplyInSlot Class
The SMX_PowerSupplyInSlot class extends the CIM_ElementInConnector class and
associates the HP_PowerSupplySlot instance with HP_PowerSupplyModuleinstances.
The following table lists the properties implemented.
Property Name
Property Implementation