HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management Power Supply Provider Overview 209
Property Name
Property Implementation
StatusDescriptions[0]
Description of the status of the power supply corresponding to the
OperationalStatus.
For example:
Power Supply is operating properlyif OperationalStatus[0]
is 2 (OK);
Power Supply is degradedif OperationalStatus[0] is 3
(Degraded)
Power Supply has failed
if
OperationalStatus
is
6
(Error)
HealthState
5 (OK) if power supply is operating properly;
10 (Degraded) if power supply is degraded
20 (Major Failure) if power supply has failed
Name
Short description of this power supply for the name displayed by the MP or iLO
and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
CIM_PhysicalElement
CreationClassName
SMX_PowerSupplyModule
PartNumber
The part number assigned by the organization that is responsible for producing
or manufacturing the
PhysicalElement
.
SerialNumber
A manufacturer-allocated number used to identify the Physical Element.
Tag
Unique identifier for this power supply instance.
CIM_PhysicalPackage
RemovalConditions
0 (Unknown)
3 (Removable when off)
4
(Removable when on or off)
PackageType
6
(PowerSupply)
12-2-12 SMX_SystemPhysicalPowerSupply Class
The SMX_SystemPhysicalPowerSupply class extends the CIM_Container class and
association of the HP_ComputerSystemChassis instance with HP_PowerSupplyModule.
The following table lists the properties implemented.