HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management Power Supply Provider Overview 209
Property Name
Property Implementation
StatusDescriptions[0]
Description of the status of the power supply corresponding to the
OperationalStatus.
For example:
Power Supply is operating properly – if OperationalStatus[0]
is 2 (OK);
Power Supply is degraded – if OperationalStatus[0] is 3
(Degraded)
Power Supply has failed
– if
OperationalStatus
is
6
(Error)
HealthState
5 (OK) – if power supply is operating properly;
10 (Degraded) if power supply is degraded
20 (Major Failure) – if power supply has failed
Name
Short description of this power supply for the name displayed by the MP or iLO
and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
CIM_PhysicalElement
CreationClassName
SMX_PowerSupplyModule
PartNumber
The part number assigned by the organization that is responsible for producing
or manufacturing the
PhysicalElement
.
SerialNumber
A manufacturer-allocated number used to identify the Physical Element.
Tag
Unique identifier for this power supply instance.
CIM_PhysicalPackage
RemovalConditions
0 (Unknown)
3 (Removable when off)
4
(Removable when on or off)
PackageType
6
(PowerSupply)
12-2-12 SMX_SystemPhysicalPowerSupply Class
The SMX_SystemPhysicalPowerSupply class extends the CIM_Container class and
association of the HP_ComputerSystemChassis instance with HP_PowerSupplyModule.
The following table lists the properties implemented.