HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management Power Supply Provider Overview 208
Property Name
Property Implementation
PhysicalLocation
References
CIM_Location
12-2-11 SMX_PowerSupplyModule Class
The SMX_PowerSupplyModule class is used to model physical power supplies on servers.
Power supply numbers for existing instances do not change when other power supplies are
added and removed.
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_ManagedElement
Caption
Short description of this power supply for the name displayed by the MP or iLO
and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
Description
Description of this power supply module, including ElementName, Type and
Status.
For example:
ElementName provides power for PowerSupplyType.
StatusDescription
Where: ElementName represents the value of ElementName,
PowerSupplyType represents the corresponding string value of the
PowerSupplyType enumeration and StatusDescription represents the
value of
StatusDescriptions[0]
.
ElementName
Short description of this power supply for the name displayed by the MP or iLO
and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) – if power supply is operating properly;
3 (Degraded) – if power supply is degraded;
6
(Error) – if power supply has failed