HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management Power Supply Provider Overview 207
Property Name
Property Implementation
Description
Description of this power supply location, including the location.
For example on HP Proliant:
The location of the power supply <n>. Please refer to power supply position
<n> printed on the system.
Where:
<
n> presents the power supply position printed on the system labeling.
ElementName
User displayable name of this power supply location, including the location.
For example:
Power Supply1 at PowerSupplySlot=2
CIM_Location
Name
Unique identifier for this power supply location instance.
PhysicalPosition
Physical position of this Power Supply.
For example on HP Proliant:
Number represents the power supply position printed on the system.
HP_Location
ElementLocationTag
Location string based on ElementLocationTagDesc.
For example, on HP Proliant:
Power Supply <n>
Where :
<
n> represents the power supply position printed on the system.
ElementLocationTagDesc
On HP Proliant:
0
(HoodTag)
LocationInfoDesc
An array of tags describing the corresponding location path information
contained in the
LocationInformation
property array.
LocationInformation
An array of string values describing the location path of a managed element
containment hierarchy.
12-2-10 SMX_PowerSupplyElementLocation Class
The SMX_PowerSupplyElementLocation class is used to represent an association between
the CIM_Location and CIM_ManagedElement classes.
The following table lists the properties implemented.
Property Name Property Implementation
Element
References
CIM_ManagedElement