HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management Power Supply Provider Overview 204
Property Name
Property Implementation
Power Redundancy Set <n>
Where:
<
n> represents the number of the redundancy set instance.
Description
Description of this redundancy set
For example:
Power Redundancy Set <n> is collection of fault tolerant power supplies that
provide redundant power
Where: <n> represents the number of the redundancy set instance.
ElementName
User printable name for this power redundancy set.
For example:
Power Redundancy Set <n>
Where: <n> represents the number of the redundancy set instance.
CIM_SystemSpecificCollection
InstanceID
Unique identifier for this power redundancy instance.
CIM_RedundancySet
MaxNumberSupported
Represents the maximum number of power supplies supported for this redundancy
set.
MinNumberNeeded
Represents the minimum number of power supplies needed to function.
TypeOfSet
3
(Load Balanced)
LoadBalanceAlgorithm
0
(Unknown)
RedundancyStatus
0 (Unknown) if the redundancy status is unknown;
2 (Fully Redundant) if the all power supplies in the set are operating properly
and enough to achieve redundancy;
3 (Degraded Redundancy) if there are at least enough power supplies for the
redundancy set to provide power, but power supplies have failed;
4 (Redundancy Lost) if there are not enough power supplies required to achieve
redundancy, but enough for the redundancy set to provide power;
5 (Overall Failure) if there are not enough power supplies operating properly for
the redundancy set to provide power.
12-2-4 SMX_MemberOfPowerRedundancy Class
The SMX_MemberOfPowerRedundancy class is used to represent an association between
HP_PowerSupply and HP_PowerRedundancySet.