HP Insight Management Power Supply Provider Overview 203
Property Name
Property Implementation
GroupOperationalStatus[0]
Represents the most severe power redundancy status and non-fault tolerant
power supply operational status:
0 (Unknown) if power collection status is unknown;
2 (OK) if power supplies are operating properly;
3 (Degraded) if no SMX_PowerSupply.OperationalStatus[0]
for
all non-fault tolerant power supplies report 6 (Error) and
SMX_PowerRedundancySet.RedundancyStatus for any power
redundancy sets report 3 (Degraded Redundancy) or 4 (Redundancy Lost)
and no power redundancy sets report 5 (Overall Failure).
6 (Error) if SMX_PowerSupply.OperationalStatus[0] for any
non-fault tolerant power supplies report 6 (Error) or
SMX_PowerRedundancySet.RedundancyStatus for any power
redundancy sets report 5 (Overall Failure).
Note: The system starts up with a redundancy status set to
4 (Redundancy Lost) and no power supplies have been
removed or failed, the GroupOperationalStatus will be set to
2 (OK) because this is a valid configuration.
GroupStatusDescriptions[0]
Unknown status for power supplies - if GroupOperationalStatus[0]
is 0 (Unknown);
Power supplies are operating properly if
GroupOperationalStatus[0] is 2 (OK);
Power supplies are degraded if GroupOperationalStatus[0] is 3
(Degraded);
Power supplies have failed if GroupOperationalStatus[0] is 6
(Error)
12-2-3 SMX_PowerRedundancySet Class
The SMX_PowerRedundancySet class is used to model power supply redundancy sets on
servers.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
Caption
Short description of this redundancy set.
For example: