HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers
HP Insight Management Power Supply Provider Overview 201
Property Name
Property Implementation
OperationalStatus[0]
2 (OK) – if power supply is operating properly;
3 (Degraded) – if power supply is degraded;
6
(Error) – if power supply has failed
OperationalStatus[1]
Extended Warning and Error status. See the MOF and Profile
StatusDescriptions[0]
Description of the status of the power supply corresponding to the
OperationalStatus.
For example:
Power Supply is operating properly– if OperationalStatus[0]
is 2 (OK);
Power Supply is degraded – if OperationalStatus[0] is 3
(Degraded)
Power Supply has failed
– if
OperationalStatus
is
6
(Error)
StatusDescriptions[1]
Description of the extended warning/error status corresponding to the
OperationalStatus[1
]. See Profile.
HealthState
5 (OK) – if power supply is operating properly;
10 (Degraded) if power supply is degraded
20
(Major Failure) – if power supply has failed
Name
Unique name of this power supply from the name displayed by the MP or iLO
and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
TimeOfLastStateChange
Time that state last changed for power supply. 0 if it has not changed since
provider startup.
CIM_LogicalDevice
CreationClassName
SMX_PowerSupply
DeviceID
Unique identifier for this power supply instance.
SystemCreationClassName
SMX_ComputerSystem.CreationClassName
SystemName
SMX_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault
2
(Enabled)