HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management Power Supply Provider Overview 201
Property Name
Property Implementation
OperationalStatus[0]
2 (OK) if power supply is operating properly;
3 (Degraded) if power supply is degraded;
(Error) if power supply has failed
OperationalStatus[1]
Extended Warning and Error status. See the MOF and Profile
StatusDescriptions[0]
Description of the status of the power supply corresponding to the
OperationalStatus.
For example:
Power Supply is operating properlyif OperationalStatus[0]
is 2 (OK);
Power Supply is degradedif OperationalStatus[0] is 3
(Degraded)
if
is
(Error)
StatusDescriptions[1]
Description of the extended warning/error status corresponding to the
]. See Profile.
HealthState
5 (OK) if power supply is operating properly;
10 (Degraded) if power supply is degraded
(Major Failure) if power supply has failed
Name
Unique name of this power supply from the name displayed by the MP or iLO
and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
TimeOfLastStateChange
Time that state last changed for power supply. 0 if it has not changed since
provider startup.
CIM_LogicalDevice
CreationClassName
DeviceID
Unique identifier for this power supply instance.
SystemCreationClassName
SystemName
CIM_EnabledLogicalElement
EnabledDefault
(Enabled)