HP Insight Management WBEM Providers 2.8 for Linux on HP ProLiant and Integrity Servers

HP Insight Management WBEM PCI Device Provider Overview 196
Property Name
Property Implementation
Additional enumerators for Cellular servers
7 (Cabinet)
6 (Chassis)
Additional enumerators for HP BladeSystem servers
14 (Blade)
1 (Mezzanine)
LocationInformation
Array of text values representing the location components that describe
this PCI Slot location. LocationInfoDesc[0] per
LocationInfornation[0].
Cross-reference with LocationInfoDescription array to determine what type
of location information is represented
11-4-9 SMX_PCISlotElementLocation
Property Name Property Implementation
Element
References
SMX_PCISlot
PhysicalLocation
References
SMX_PCISlotLocation
11-5 Physical Location
The Physical Location is a string representing the physical location of any PCI device. This
string should represent the physical location of the device from which an end-user can
uniquely locate the device. Most of these strings will be visible in customer documentation,
silkscreen labels, or hood tags.
The following table lists the properties implemented. Any combination of the following
applicable descriptors could be used to better define the device location.
All Systems
HP Integrity
Cellular Servers
HP
BladeServers in C3000 /
C7000 Enclosures
Slot=<
num
>
Cabinet=<
num
>
Blade=<
num
>
Embedded
Controller=<logical_controller_id>
Bay=<num>
RootPort=<num> (if
embedded on System
Board)
Mezzanine=<num> Chassis=<num>
Mezzanine=<num> (I/O
Mezzanine slot num)